Original Research

Wideband acoustic immittance for assessing middle ear functioning for preterm neonates in the neonatal intensive care unit

Nandel Gouws, De Wet Swanepoel, Leigh Biagio de Jager
South African Journal of Communication Disorders | Vol 64, No 1 | a182 | DOI: https://doi.org/10.4102/sajcd.v64i1.182 | © 2017 Nandel Gouws, De Wet Swanepoel, Leigh Biagio de Jager | This work is licensed under CC Attribution 4.0
Submitted: 30 August 2016 | Published: 28 June 2017

About the author(s)

Nandel Gouws, Department of Speech-Language Pathology and Audiology, University of Pretoria, South Africa
De Wet Swanepoel, Department of Speech-Language Pathology and Audiology, University of Pretoria, South Africa
Leigh Biagio de Jager, Department of Speech-Language Pathology and Audiology, University of Pretoria, South Africa

Abstract

Background: The primary aim of newborn hearing screening is to detect permanent hearing loss. Because otoacoustic emissions (OAEs) and automated auditory brainstem response (AABR) are sensitive to hearing loss, they are often used as screening tools. On the other hand, false-positive results are most often because of transient outer- and middle ear conditions. Wideband acoustic immittance (WAI), which includes physical measures known as reflectance and absorbance, has shown potential for accurate assessment of middle ear function in young infants.

Objective: The main objective of this study was to determine the feasibility of WAI as a diagnostic tool for assessing middle ear functioning in preterm neonates in the neonatal intensive care unit (NICU) designed for premature and ill neonates. A further objective was to indicate the difference between the reflectance values of tones and click stimuli.

Method: Fifty-six at-risk neonates (30 male and 26 female), with a mean age at testing of 35.6 weeks (range: 32–37 weeks) and a standard deviation of 1.6 from three private hospitals, who passed both the distortion product otoacoustic emission (DPOAE) and AABR tests, were evaluated prior to discharge from the NICU. Neonates who presented with abnormal DPOAE and AABR results were excluded from the study. WAI was measured by using chirp and tone stimuli. In addition to reflectance, the reflectance area index (RAI) values were calculated.

Results: Both tone and chirp stimuli indicated high-power reflectance values below a frequency of 1.5 kHz. Median reflectance reached a minimum of 0.67 at 1 kHz – 2 kHz but increased to 0.7 below 1 kHz and 0.72 above 2 kHz for the tone stimuli. For chirp stimuli, the median reflectance reached a minimum of 0.51 at 1 kHz – 2 kHz but increased to 0.68 below 1 kHz and decreased to 0.5 above 2 kHz. A comparison between the present study and previous studies on WAI indicated a substantial variability across all frequency ranges.

Conclusion: These WAI measurements conducted on at-risk preterm NICU neonates (mean age at testing: 35.6 weeks, range: 32–37 weeks) identified WAI patterns not previously reported in the literature. High reflective values were obtained across all frequency ranges. The age of the neonates when tested might have influenced the results. The neonates included in the present study were very young preterm neonates compared to the ages of neonates in previous studies. WAI measured in at-risk preterm neonates in the NICU was variable with environmental and internal noise influences. Transient conditions affecting the sound-conduction pathway might have influenced the results. Additional research is required to investigate WAI testing in ears with and without middle ear dysfunction. The findings of the current study imply that in preterm neonates it was not possible to determine the feasibility of WAI as a diagnostic tool to differentiate between ears with and without middle ear pathology.


Keywords

Newborn hearing screening; Otoacoustic emissions; Automated Auditory Brainstem Response; Wideband Acoustic Immittance; Neonatal Intensive Care Unit; Middle-ear functioning

Metrics

Total abstract views: 3677
Total article views: 4085

 

Crossref Citations

1. Differences between Pressurized and Non-Pressurized Transient-Evoked Otoacoustic Emissions in Neonatal Subjects
Giovanna Zimatore, Piotr Henryk Skarzynski, Federica Di Berardino, Eliana Filipponi, Stavros Hatzopoulos
Audiology and Neurotology  vol: 26  issue: 5  first page: 346  year: 2021  
doi: 10.1159/000512762